"S" Beam Type 200/300kg
Output impendence 350Ω
Input Impedance 400 ±20Ω
Safe overload 150% rated capacity
Ultimate overload 300% rated capacity
The additional sense wires compensate for changes in lead resistance due to temperature changes and/or cable extension.
For use in tension and compression
6 wire (sense) circuit
Bridge signal conditioners available separately
For Output signal conditioners see (stock no.
455-5043
)
Dimensions 62 x 80 x 18mm
Applications:
Include Force measurement, material testing machines, conversion of mechanical scales to electronic, hanging scales, hoppers
Cable Type
Cable Length (m)
Insulation Resistance (Ω)
Excitation Voltage (V)
Compensated Temperature Range (°C)
IP Rating
Operating Temperature Range (°C)
6 Conductors; 26 AWG; Braid Shield; PVC Jacket
3
>2 x 10
9
10 ac/dc
-10 to +45
IP67
-30 to +70