Products Found: 44

Showing Results For: Motor Protection Circuit Breakers

Motor Protection Circuit Breakers


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Rohs Verified
222413 | PKZM4-63, Eaton
5 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 205.06
10 +
£ 192.75
15 +
£ 184.55
Rohs Verified
088913 | PKZM0-2,5-T, Eaton
6 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 69.63
10 +
£ 65.45
15 +
£ 62.67
Rohs Verified
088918 | PKZM0-20-T, Eaton
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 86.50
10 +
£ 81.32
15 +
£ 77.84
Rohs Verified
088909 | PKZM0-0,4-T, Eaton
6 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 76.75
10 +
£ 72.12
15 +
£ 69.06
Rohs Verified
222354 | PKZM4-40, Eaton
15 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 170.52
10 +
£ 160.28
15 +
£ 153.46
Rohs Verified
046938 | PKZM0-16, Eaton
86 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 103.90
10 +
£ 97.65
15 +
£ 93.49
Rohs Verified
PKZM01-2,5, Eaton
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 88.82
Rohs Verified
PKZM01-10, Eaton
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 103.15
Rohs Verified
PKZM0-20, Eaton
11 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 134.10
Rohs Verified
PKZM01-16, Eaton
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 103.15
Rohs Verified
PKZM01-4, Eaton
11 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 88.82
Rohs Verified
PKZM0-16, Eaton
18 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 123.42
Rohs Verified
PKZM4-16, Eaton
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 189.33
Eaton
Rohs Verified
PKE32, Eaton
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 84.58
Eaton
PKZM0-1, Eaton
5 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 105.85
Rohs Verified
PKZM0-0,63, Eaton
6 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 94.12
Eaton
PKZM0-4, Eaton
20 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 105.85
PKZM0-10, Eaton
9 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 123.42
Schneider Electric
Rohs Verified
GV7RE50, Schneider Electric
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 310.77
Showing
1 -

New Items
New items
088912 | PKZM0-1,6-T, Eaton

088912 | PKZM0-1,6-T, Eaton

Transformer Protection Switches, PKZM0-T DIN rail mounted, mechanically reset protection devices. Transformer short circuit and overload protection The short circuit release is set to 20 x I u , so even transformers that have high inrush currents have protection Rotary handle for ease of trip indication after a fault has occurred Rated operational voltage 690V Trip-fault indication Phase failure sensitive 93 x 45 x 76mm (H x W x D) Note PKZMO accessories can be used allowing additional functions.
New items
278475 | PKZM01-0,16, Eaton

278475 | PKZM01-0,16, Eaton

Eaton Motor Protective Circuit Breaker - PKZM0 Eaton's reliable and robust motor protection circuit breakers are the perfect solution for protecting your motors from faults such as an overload of high voltages, short circuits or relay shutdowns. Down-time of machinery can be detrimental to a business and its operations, Eaton's PKZM0 range of motor protection circuit breakers has been created and designed to act as an intermediary between your devices, protecting vital equipment in the event of unforeseen incidents. This reduces the amount of downtime of machinery to enable operations to continue running smoothly. Features & Benefits Rated operating voltage 690Vac Operating temperature range -25°C to +55°C Temperature compensated range -5°C to +40°C Adjustable current trip level, 0.6 – 1.0 x nominal rating Short-circuit trip level (fixed) 14x nominal rating Single-phase-failure sensitivity to IEC60947-4-1 Simple two-button operation for starting and stopping motors May be locked in the "off" position How do I select the right Motor Protection Circuit Breaker? MPCBs are more critical now than ever. Most infrastructures now rely on a motor behind the scenes to power critical uninterruptible systems such as heating, ventilation and cooling. These systems are vital in ensuring business continues as usual, therefore must be protected against overcurrent's, thermal overloads and similar problems. To select the right MPCB, consider the systems you and your business rely upon. Checking the features and benefits of each MPCB will prove invaluable when deciding what critical infrastructure you wish to protect. Standards IEC (EN60) 947-1 general, 947-2 Circuit breakers, 1-4 switch disconnectors, 1-5 Motor starters, 1-6 Electrical equipment of machines Approvals UL, CSA, LROS, GL
New items
088910 | PKZM0-0,63-T, Eaton

088910 | PKZM0-0,63-T, Eaton

Transformer Protection Switches, PKZM0-T DIN rail mounted, mechanically reset protection devices. Transformer short circuit and overload protection The short circuit release is set to 20 x I u , so even transformers that have high inrush currents have protection Rotary handle for ease of trip indication after a fault has occurred Rated operational voltage 690V Trip-fault indication Phase failure sensitive 93 x 45 x 76mm (H x W x D) Note PKZMO accessories can be used allowing additional functions.
New items
GV7RE50, Schneider Electric

GV7RE50, Schneider Electric

Motor Protection Circuit Breakers, GV7-R The GV7-R MPCB can easily be fitted by screw fixing or DIN rail mounting Toggle lever control Connection by screw clamp Power circuit voltage: 220 / 240V Selection Guide Stock No. Breaking Capacity (kA) Motor Power (kW) 608-8860 70 7.5 608-8826 25 11 608-8832 25 15 608-8876 70 15 608-8797 25 18.5 608-8848 70 18.5 608-8804 35 35 608-8854 70 35 608-8810 35 55
New items
278482 | PKZM01-4, Eaton

278482 | PKZM01-4, Eaton

Eaton Motor Protective Circuit Breaker - PKZM0 Eaton's reliable and robust motor protection circuit breakers are the perfect solution for protecting your motors from faults such as an overload of high voltages, short circuits or relay shutdowns. Down-time of machinery can be detrimental to a business and its operations, Eaton's PKZM0 range of motor protection circuit breakers has been created and designed to act as an intermediary between your devices, protecting vital equipment in the event of unforeseen incidents. This reduces the amount of downtime of machinery to enable operations to continue running smoothly. Features & Benefits Rated operating voltage 690Vac Operating temperature range -25°C to +55°C Temperature compensated range -5°C to +40°C Adjustable current trip level, 0.6 – 1.0 x nominal rating Short-circuit trip level (fixed) 14x nominal rating Single-phase-failure sensitivity to IEC60947-4-1 Simple two-button operation for starting and stopping motors May be locked in the "off" position How do I select the right Motor Protection Circuit Breaker? MPCBs are more critical now than ever. Most infrastructures now rely on a motor behind the scenes to power critical uninterruptible systems such as heating, ventilation and cooling. These systems are vital in ensuring business continues as usual, therefore must be protected against overcurrent's, thermal overloads and similar problems. To select the right MPCB, consider the systems you and your business rely upon. Checking the features and benefits of each MPCB will prove invaluable when deciding what critical infrastructure you wish to protect. Standards IEC (EN60) 947-1 general, 947-2 Circuit breakers, 1-4 switch disconnectors, 1-5 Motor starters, 1-6 Electrical equipment of machines Approvals UL, CSA, LROS, GL Eaton PKZM01-4 MPCB ...
New items
046989 | PKZM0-25, Eaton

046989 | PKZM0-25, Eaton

Eaton Motor Protective Circuit Breaker - PKZM0 Eaton's reliable and robust motor protection circuit breakers are the perfect solution for protecting your motors from faults such as an overload of high voltages, short circuits or relay shutdowns. Down-time of machinery can be detrimental to a business and its operations, Eaton's PKZM0 range of motor protection circuit breakers has been created and designed to act as an intermediary between your devices, protecting vital equipment in the event of unforeseen incidents. This reduces the amount of downtime of machinery to enable operations to continue running smoothly. Features & Benefits • DIN-rail mounting • Forms part of the xStart family of control gear products • Typical moto protection accessories – Shunt release 492-1709 & 492-1715 , lockable rotary handle 244-0113 • Rated operating voltage 690Vac How do I select the right Motor Protection Circuit Breaker? MPCBs are more critical now than ever. Most infrastructures now rely on a motor behind the scenes to power critical uninterruptible systems such as heating, ventilation and cooling. These systems are vital in ensuring business continues as usual, therefore must be protected against overcurrent's, thermal overloads and similar problems. To select the right MPCB, consider the systems you and your business rely upon. Checking the features and benefits of each MPCB will prove invaluable when deciding what critical infrastructure you wish to protect. Eaton PKZM0-25 MPCB Rotary Switch Operated 3 pole Forms part of the PKZMO motor protective circuit-breakers up to 32 A Also suitable for motors with efficiency class IE3 Screw terminals IP20 degree of protection. This offers protection against solid objects up to 12 mm but no protection against liquids. Overload releases 20 - 25
New items
PKZM01-2,5, Eaton

PKZM01-2,5, Eaton

PKZM01 Pushbutton Operated MPCB Modular Motor Protective Circuit Breakers designed for use with add-on contactor modules and accessories (see below) which provide isolation, short circuit and thermal protection. The units are DIN-rail mounting and part of the xStart family of control gear products, and a range of connection and wiring accessories are available to speed up assembly work and minimise wiring errors.,Various enclosure options are available, see PKZM Enclosures range. Rated operating voltage 690Vac Operating temperature range -25°C to +55°C Temperature compensated range -5°C to +40°C Adjustable current trip level, 0.6 – 1.0 x nominal rating Short-circuit trip level (fixed) 14x nominal rating Single-phase-failure sensitivity to IEC60947-4-1 Simple two-button operation for starting and stopping motors May be locked in the "off" position Approvals UL, CSA, LROS, GL Standards IEC (EN60) 947-1 general, 947-2 Circuit breakers, 1-4 switch disconnectors, 1-5 Motor starters, 1-6 Electrical equipment of machines
New items
278483 | PKZM01-6,3, Eaton

278483 | PKZM01-6,3, Eaton

Eaton Motor Protective Circuit Breaker - PKZM0 Eaton's reliable and robust motor protection circuit breakers are the perfect solution for protecting your motors from faults such as an overload of high voltages, short circuits or relay shutdowns. Down-time of machinery can be detrimental to a business and its operations, Eaton's PKZM0 range of motor protection circuit breakers has been created and designed to act as an intermediary between your devices, protecting vital equipment in the event of unforeseen incidents. This reduces the amount of downtime of machinery to enable operations to continue running smoothly. Features & Benefits Rated operating voltage 690Vac Operating temperature range -25°C to +55°C Temperature compensated range -5°C to +40°C Adjustable current trip level, 0.6 – 1.0 x nominal rating Short-circuit trip level (fixed) 14x nominal rating Single-phase-failure sensitivity to IEC60947-4-1 Simple two-button operation for starting and stopping motors May be locked in the "off" position How do I select the right Motor Protection Circuit Breaker? MPCBs are more critical now than ever. Most infrastructures now rely on a motor behind the scenes to power critical uninterruptible systems such as heating, ventilation and cooling. These systems are vital in ensuring business continues as usual, therefore must be protected against overcurrent's, thermal overloads and similar problems. To select the right MPCB, consider the systems you and your business rely upon. Checking the features and benefits of each MPCB will prove invaluable when deciding what critical infrastructure you wish to protect. Standards IEC (EN60) 947-1 general, 947-2 Circuit breakers, 1-4 switch disconnectors, 1-5 Motor starters, 1-6 Electrical equipment of machines Approvals UL, CSA, LROS, GL
New items
088915 | PKZM0-6,3-T, Eaton

088915 | PKZM0-6,3-T, Eaton

Transformer Protection Switches, PKZM0-T DIN rail mounted, mechanically reset protection devices. Transformer short circuit and overload protection The short circuit release is set to 20 x I u , so even transformers that have high inrush currents have protection Rotary handle for ease of trip indication after a fault has occurred Rated operational voltage 690V Trip-fault indication Phase failure sensitive 93 x 45 x 76mm (H x W x D) Note PKZMO accessories can be used allowing additional functions.
New items
088916 | PKZM0-10-T, Eaton

088916 | PKZM0-10-T, Eaton

Transformer Protection Switches, PKZM0-T DIN rail mounted, mechanically reset protection devices. Transformer short circuit and overload protection The short circuit release is set to 20 x I u , so even transformers that have high inrush currents have protection Rotary handle for ease of trip indication after a fault has occurred Rated operational voltage 690V Trip-fault indication Phase failure sensitive 93 x 45 x 76mm (H x W x D) Note PKZMO accessories can be used allowing additional functions.
New items
PKZM0-1, Eaton

PKZM0-1, Eaton

PKZM0 Rotary Switch Operated MPCB Modular Motor Protective Circuit Breakers designed for use with add-on contactor modules and accessories which provide isolation, short circuit and thermal protection. The units are DIN-rail mounting and part of the xStart family of control gear products, and a range of connection and wiring accessories are available to speed up assembly work and minimise wiring errors.,Various enclosure options are available, see PKZM Enclosures range. Rated operating voltage 690Vac Operating temperature range -25°C to +55°C Temperature compensated range -5°C to +40°C Adjustable current trip level, 0.6 – 1.0 x nominal rating Short-circuit trip level (fixed) 14x nominal rating Single-phase-failure sensitivity to IEC60947-4-1 Dimensions 195 x 45 x 77 (HxWxD) mm Rotary switch operation with padlockable handle option, see accessories On/Off/Tripped indication may be locked in the "off" position with handle Approvals UL, CSA, LROS, GL Standards IEC (EN60) 947-1 general, 947-2 Circuit breakers, 1-4 switch disconnectors, 1-5 Motor starters, 1-6 Electrical equipment of machines
New items
088911 | PKZM0-1-T, Eaton

088911 | PKZM0-1-T, Eaton

Transformer Protection Switches, PKZM0-T DIN rail mounted, mechanically reset protection devices. Transformer short circuit and overload protection The short circuit release is set to 20 x I u , so even transformers that have high inrush currents have protection Rotary handle for ease of trip indication after a fault has occurred Rated operational voltage 690V Trip-fault indication Phase failure sensitive 93 x 45 x 76mm (H x W x D) Note PKZMO accessories can be used allowing additional functions.
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Motor Protection Circuit Breakers and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Motor Protection Circuit Breakers or any other product.
This depends on the Motor Protection Circuit Breakers individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Motor Protection Circuit Breakers and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Motor Protection Circuit Breakers.
Yes. We keep updating our stock frequently and if a product like Motor Protection Circuit Breakers is not in stock then we will let you know.