Products Found: 997

Showing Results For: RCCBs

RCCBs

RCCBs (Residual-Current Circuit Breakers) are protective devices designed to protect electrical circuits against overloads, current leakage, or tripping caused by indirect contact. These devices ensure to safeguard individuals and equipment from electrical shocks, fires, or electrocution and act as main disconnecting switches. Additionally, these robust devices are the most convenient and ultimate protection sources for residential equipment and people by preventing dynamic stresses and overloads.

What are the key benefits of residential RCCBs?

These residential circuit breakers feature unmatchable benefits, such as:

  • They feature safe performance, guaranteed with global brand certification.
  • Offer easy integration into DIN rails with slider actuators.
  • Space saving with compact designs for residual and line current protection.
  • Come as a complete range of products with accessories.
  • Many package options are available with robust overload and shock protection.

RCCBs are divided into:

Generally, residual current circuit breakers come with 2, 3, or 4 poles as DIN rail mounted. They are distinguished based on their trip sensitivity, current ratings, and tripping features that must be considered carefully before buying or using them for particular applications. 

What is the difference between MCBs and RCCBs? 

MCBs, miniature circuit breakers, and RCCBs are both circuit protection devices with prominent but contrasting functions. MCBs are designed to protect against overcurrent and short circuits, whereas RCCBs provide protection against electric shocks and earth leakages only. However, their combined operations are ideal for robust and effective protection purposes.

Where are RCCBs used?

They are widely used in domestic, commercial, and industrial areas and are particularly ideal for environments where devices like medical equipment, frequency converters, and UPS systems are consistently on the run.


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Rohs Verified
2CSF204592R3250 F204 B-25/0,3, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 828.10
5 +
£ 786.70
10 +
£ 745.29
Rohs Verified
2CSF204592R3630 F204 B-63/0,3, ABB
4 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 899.62
5 +
£ 854.64
10 +
£ 809.66
Rohs Verified
2CCL562111E1064, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 84.50
Rohs Verified
2CCL562330E1064 FS401MK-C6/0.03, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 190.59
Rohs Verified
2CCL562330E1104 FS401MK-C10/0.03, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 190.59
Rohs Verified
2CCL562330E1204 FS401MK-C20/0.3, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 207.35
Rohs Verified
2CCL562330E1324 FS401MK-C32/0.3, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 221.77
Rohs Verified
2CCL563120E0204, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 298.75
Rohs Verified
2CCL563120E0254, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 298.75
Rohs Verified
2CCL564110E0135 FS403M-B13/0.03, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 300.44
Rohs Verified
P1RC4P40B300, Lovato
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 863.21
Siemens
Rohs Verified
5SM2342-0, Siemens
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 85.36
Schneider Electric
Rohs Verified
A9R51440, Schneider Electric
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 64.62
Schneider Electric
Rohs Verified
A9R91463, Schneider Electric
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 129.24
Rohs Verified
EUR125.100/4, Europa
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 62.79
Merlin Gerin
Rohs Verified
18690, Merlin Gerin
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 489.00
5 +
£ 475.44
P1RC2P40AC030, Lovato
2 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 101.62
5 +
£ 96.44
Contactum
Rohs Verified
CPR100003, Contactum
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 69.70
Rohs Verified
2CCL562122E0254, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 154.59
Rohs Verified
2CCL562310E1254 FS401MK-C25/0.03, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 221.77
Rohs Verified
2CCL562310E1325 FS401MK-B32/0.03, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 199.61
Rohs Verified
2CCL562330E1134 FS401MK-C13/0.3, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 207.35
Rohs Verified
2CCL563120E0134, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 298.75
Rohs Verified
2CCL564110E0064, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 332.29
Rohs Verified
2CCL564111E0104, ABB
Pre Order
Check Stock & Lead Times Packaging Options
1 +
£ 228.49
Showing
1 -

New Items
New items
2CSF204592R3630  F204 B-63/0,3, ABB

2CSF204592R3630 F204 B-63/0,3, ABB

Details that make the difference: Type B residual current devices are marked according to EN 62423. Easy to connect and compatible with busbars thanks to the System pro M compact clamps. Sole two-pole device in only two modules on the market. VDE approved. Green LED to monitor operation of the residual current circuit breaker. Indication of the position of the contacts. Compact and functional design The new F200 B RCCBs feature an innovative design that makes the products compact. Indeed, the two-pole device is the first one on the market that is built in just two modules and its compact dimensions ensure significant space savings in the switchboard. The new range of F200 B RCCBs is certified by the IMQ and VDE markings for operation in extremely harsh weather conditions up to 60 °C. FI F204B+63/0,3 Residual Current Circuit Breaker
New items
EUR125.100/4, Europa

EUR125.100/4, Europa

Europacomponents EUR1 Series RCCB Europa Components EUR1 RCCB series provide ground fault protection by monitoring the leakage of current to ground when used with standard MCBs. The EUR1 series are compact DIN Rail-mounted RCCBs and feature a wide range of trip ratings to offer complete protection for commercial or industrial applications. Compact AC DIN Rail mount 2 and 4 Pole RCCB’s Protects against the effects of sinusoidal alternating earth fault currents Protects against indirect contact, with additional protection against direct contact Command and isolation of resistive and inductive circuits Suitable for residential and commercial applications Note RCCBs are sensitive only to earth fault current (therefore they have to be connected in series with an MCB or a fuse to protect them against overcurrent and short circuits). Europacomponents Circuit Protection Devices
New items
236778 PXF-40/4/03-A, Eaton

236778 PXF-40/4/03-A, Eaton

Eaton Residual Current Circuit Breakers (RCCBs) - PXF-A Series Features & Benefits What type of RCD do I need? Fixed RCDs Socket-Outlet RCD Portable RCD plugs
New items
236726 PXF-16/2/001-A, Eaton

236726 PXF-16/2/001-A, Eaton

Eaton Residual Current Circuit Breakers (RCCBs) - PXF-A Series Features & Benefits What type of RCD do I need? Fixed RCDs Socket-Outlet RCD Portable RCD plugs
New items
5SV3342-4, Siemens

5SV3342-4, Siemens

The Siemens 5SV3 series residual current operated circuit breaker or RCCB is suitable for personnel and fire protection. The circuit breaker is available in either 2 or 4 pole versions and each breaker can be DIN rail mounted. The 5SV3 RCCBs offer highly reliable performance and excellent quality. The break time is short-time delayed and provides protection against residual currents. It provides easy and safe installation. Silicone Free Instant tripping Surge current withstand capability >1kA Equipment life span: >10,000 switching cycles Enclosure: IP20 Ambient temperature: -25→+45 °C
New items
5SV3314-3, Siemens

5SV3314-3, Siemens

The residual current operated circuit breaker is a 2-pole, type F, short-time delayed unit. In the event of an overload or short-circuit, circuit breakers safely cut off the connected circuit and reliably protect electrical installations and equipment from damage. The RCD is the residual current device for touch protection. Siemens offers a comprehensive portfolio of protection, switching, measuring and monitoring devices. It is a simple distribution systems as well as switches and sockets for safe and efficient electrical infrastructure in buildings and industry. Tripping fault current 30 mA AC operating current 40 A
New items
M9R81263, Schneider Electric

M9R81263, Schneider Electric

The Schneider Electric Multi GFP residual current circuit breaker. It is a 2P circuit breaker with 63A In rated current, a sensitivity of 26mA with a A-SI type protection class. It protects persons against electric shock by direct contact. It also protects installations against fire risks. The tripping upon fault is indicated by a red mechanical status indicator on the front panel. storage temperature -40°C to 70°C
New items
5SV3311-6, Siemens

5SV3311-6, Siemens

Series 5SV3 RCCBs Professional range of Siemens RCCB's from the 5SV3 series. Available in 2 or 4 pole verisions. Each breaker can be DIN Rail mounted. All models are highly reliable and excellent quality. Residual Current operated circuit breaker for Personnel and fire protection Silicone Free 2 or 4 pole Instant tripping, surge current withstand capability >1kA DIN rail mounting Equipment life span: >10 000 Switching cycles Enclosure: IP20 Ambient temperature: -25→+45 °C Break Time - Instantaneous Safe Protection against Residual Currents New Type for More Convenience Easy and Safe Installation Siemens RCDs, RCBOs, RCCBs and MCBs Type B characteristic offers instantaneous short circuit response level of 3-5 x normal rated current, making it suitable for circuits with moderate inrush currents such as filament lamps, heating loads and most domestic/small building protection applications.,Type C characteristic offers short circuit response of 5-10 x normal rated current, making it ideal for circuits with higher inrush currents such as motor control and fluorescent lighting installations in industrial buildings where nuisance tripping might occur if a faster type was used. Type D characteristic is designed for high inrush loads. Magnetic trip point - 10 to 20 times In rating. Thermal trip point - 1.13 to 1.45 protector rating. Type AC characteristic ensure tripping for sinusoidal, alternating currents, whether they be quickly applied or slowly to increase.
New items
236775 PXF-25/4/05-A, Eaton

236775 PXF-25/4/05-A, Eaton

Eaton Residual Current Circuit Breakers (RCCBs) - PXF-A Series Features & Benefits What type of RCD do I need? Fixed RCDs Socket-Outlet RCD Portable RCD plugs
New items
235423 PFIM-16/2/003-A-MW, Eaton

235423 PFIM-16/2/003-A-MW, Eaton

PFIM Series Professional range of Eaton compact residual current devices from the PFIM series. Each device incorporates a real contact position indictor. Ideal for fault current/residual current protection and extra protection in a wide range of application. Various tripping current ratings are available.
New items
235435 PFIM-25/4/003-A-MW, Eaton

235435 PFIM-25/4/003-A-MW, Eaton

PFIM Series Professional range of Eaton compact residual current devices from the PFIM series. Each device incorporates a real contact position indictor. Ideal for fault current/residual current protection and extra protection in a wide range of application. Various tripping current ratings are available.
New items
235408 PFIM-25/4/03-MW, Eaton

235408 PFIM-25/4/03-MW, Eaton

PFIM Series Professional range of Eaton compact residual current devices from the PFIM series. Each device incorporates a real contact position indictor. Ideal for fault current/residual current protection and extra protection in a wide range of application. Various tripping current ratings are available.
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like RCCBs and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding RCCBs or any other product.
This depends on the RCCBs individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for RCCBs and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including RCCBs.
Yes. We keep updating our stock frequently and if a product like RCCBs is not in stock then we will let you know.