Products Found: 30

Showing Results For: Power Quality Analyser Accessories

Power Quality Analyser Accessories


FILTERS
Filters
Showing
1 -
Enrgtech #
Manufacturer Part No
Name
Availability
Price
Rating
Keysight Technologies
BV9211B/R-X4H-004-L, Keysight Technologies
3 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 972.66
Chauvin Arnoux
Rohs Verified
P01102057, Chauvin Arnoux
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 119.33
Keysight Technologies
Rohs Verified
BV9201B (Perpetual), Keysight Technologies
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 2017.78
Keysight Technologies
Rohs Verified
BV9201B, Keysight Technologies
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 2017.78
Keysight Technologies
Rohs Verified
BV9201B 12 Month, Keysight Technologies
1 In Stock
Check Stock & Lead Times Packaging Options
1 +
£ 597.56
Showing
1 -

New Items
New items
BV9201B (12 Month), Keysight Technologies

BV9201B (12 Month), Keysight Technologies

The Keysight Technologies pathwave benchvue advanced power control and analysis software for advanced power supplies was designed to give you fast and easy access to the advanced sourcing and measurement functionality of your N6705 DC power analyser, RP7900 Series Regenerative Power System, and Advanced Power System N7900 Series power supplies. one instrument connection Setup short-term measurements
New items
I430-FLEXI-TF-II, Fluke

I430-FLEXI-TF-II, Fluke

i430-Flexi-TF-II 6000A Flexible AC Current Probe The i430-Flexi-TF-II flexible AC current probe is optimized for current measurement on thick and hard to reach conductors. The i430-Flexi-TF-II is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II. Measuring range: 0.5 to 6000 A ac Bandwidth (-3 dB): 10 Hz to 10 kHz Output signal: 86.6 mV at 1000A/50Hz (on 1 MΩ), 85.0 mV at 1000A/50Hz (on 50 kΩ) Maximum non-destructive current: 100 kA (50/60 Hz) Transducer length: 610 mm (24 in) Transducer diameter: 7.5 mm (0.3 in) Minimum bending radius: 38 mm (1.5 in) Cable length from transducer to BNC: 2.5 m (98.4 in) Complies with: IEC 61010-1: Pollution degree 2, IEC 61010-2-032: 1000V CAT III/ 600V CAT IV, IEC 61010-031 Supplied with Instruction Sheet
New items
I430-FLEXI-TF-II-4PK, Fluke

I430-FLEXI-TF-II-4PK, Fluke

i430-Flexi-TF-II 6000A Flexible AC Current Probe The i430-Flexi-TF-II flexible AC current probe is optimized for current measurement on thick and hard to reach conductors. The i430-Flexi-TF-II is a flexible AC current probe for use with the Fluke 430 series Power Quality Analyzers including Series II. Measuring range: 0.5 to 6000 A ac Bandwidth (-3 dB): 10 Hz to 10 kHz Output signal: 86.6 mV at 1000A/50Hz (on 1 MΩ), 85.0 mV at 1000A/50Hz (on 50 kΩ) Maximum non-destructive current: 100 kA (50/60 Hz) Transducer length: 610 mm (24 in) Transducer diameter: 7.5 mm (0.3 in) Minimum bending radius: 38 mm (1.5 in) Cable length from transducer to BNC: 2.5 m (98.4 in) Complies with: IEC 61010-1: Pollution degree 2, IEC 61010-2-032: 1000V CAT III/ 600V CAT IV, IEC 61010-031 Supplied with Instruction Sheet
New items
P01102149, Chauvin Arnoux

P01102149, Chauvin Arnoux

The Chauvin Arnoux reeling box is designed for measurement leads. It comes with a magnet
New items
P01120568, Chauvin Arnoux

P01120568, Chauvin Arnoux

The Chauvin Arnoux MA196 flexible current clamp is compatible with the Qualistar and PEL product families. The Flexible AC current sensor has measurement range from 100 mA to 10,000 A (depending on the instrument). It has clamping diameter 100mm and length of flexible part 350 mm. It belongs to IEC 61010 1000V CAT III and 600V CAT IV It has operating temperature range from -10°C to + 55°C
New items
BV9210B/R-X4H-004-L, Keysight Technologies

BV9210B/R-X4H-004-L, Keysight Technologies

The Keysight Technologies BV9210B Pathwave BenchVue Advanced Battery Test and Emulation application software provides a test environment for you to easily run battery tests, generate battery models and perform battery emulation using one or more Keysight two-quadrant power supplies. The emulation function allows you to quickly output the desired battery operation conditions. Tests and emulates batteries up to 200kW and up to 2000V Supports four modes of operation: emulation, profiler, discharge/charge, and cycler Creates custom battery models Controls up to four instruments at a time Includes API functions to facilitate integration into your programming environment Provides advanced control capabilities - capacity rating, state of charge, constant or dynamic level selection, pulse width control
New items
C437-II, Fluke

C437-II, Fluke

Fluke 434 Series II; 435 Series II; 437 Series II 3-Phase Power Quality Analyser The new Fluke 430 Series II Three-Phase Power Quality and Energy Analysers provide you with more detailed power quality analysis capability, and a new Fluke-patented energy monetization function. The Fluke 434 Series II and 435 Series II offer the best in power quality analysis and introduce, for the first time ever, the ability to monetarily quantify energy losses. The new Fluke 434, 435 and 437 Series II models help locate, predict, prevent, and troubleshoot power quality problems in three-phase and single-phase power distribution systems. Additionally, the Fluke-patented energy loss algorithm, Unified Power Measurement, measures and quantifies energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy waste within a system. Features & Benefits • Energy loss calculator: Classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint the fiscal costs of energy losses. • Troubleshoot real-time: Analyze the trends using the cursors and zoom tools. • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance. • Measure all three phases and neutral: With included four flexible current probes with enhanced thin flex design to fit into the tightest places. • Automatic trending: Every measurement is always automatically recorded, without any set-up. • System-monitor: Ten power quality parameters on one screen according to EN50160 power quality standard. • Logger function: Configure for any test condition with memory for up to 600 parameters at user defined intervals...
New items
FLUKE VR1710, Fluke

FLUKE VR1710, Fluke

Fluke 1710 Single-Phase Voltage Quality Recorder The Fluke VR1710 is a single-phase, plug-in voltage quality recorder. An extremely easy-to-use solution for detecting and recording voltage quality problems, it allows for immediate action and less downtime. Features & Benefits • Fast and easy recording of voltage trends, dropouts, and power quality – pinpoints the root cause of single phase voltage problems • Easy to use – plus directly into the mains power socket and capture data • Continuous recording of all values with no gaps – saves testing time by getting the whole picture and records both events and voltage • Clear graphical summary of data and quick overview of key power quality parameters • Min, Max, and Average RMS values (1/4 cycle) with time stamp – quickly identifies what happened and when • Actual transient display (>100 μs) with time stamp – identifies power quality issues quickly with included graphical software • Flicker recording to EN 61000-4-15, individual harmonic and THD values with trends – identifies if the problem is power quality or equipment related • Statistical analysis of single phase voltage events - reduces analysis time by tracking event quantities and magnitudes • Includes PowerLog software package for quick download, analysis, and automatic reporting – Save time by generating power quality reports automatically with pre-set templates • Remote access capability via USB port to an external modem Operating voltage 70 V to 300 V Min/Max/Avg RMS value Resolution 0.125 V Number of events 175,000 Dips/Interruptions Yes Time resolution 5 ms Voltage resolution 0.125 V Over-voltages Yes Frequency Yes Harmonics measurement EN 61000-4-7 (up to 32nd) Flicker measurement EN 61000-4-15 Number of recording channels 1 Phase to Neutral 2 Phase/Neutral to Ground Recording time 1 day to 339 days depending on average time from 1 second to...
New items
P01106194, Chauvin Arnoux

P01106194, Chauvin Arnoux

The Chauvin Arnoux P01106194 AC current clamp are ideal for measure current flowing in cable without opening the cable and clamp has fixed and detachable arm. 0.05-200 A current can measure by clamp, clamping diameter of clamp is 16mm. Operating range of clamp 10 °C to +55 °C. Clamp has 3 m long shielded cord. It also insulate the user from dangerous voltages in the circuit. Measurement range 0.05-200 A Clamping diameter 16mm Weight approx. 250 g Dimensions (L x W x H) 130 x 46 x 34 mm
New items
HZC815-UK, Rohde & Schwarz

HZC815-UK, Rohde & Schwarz

Rohde & Schwarz HZC815 Mains Adapters for HMC8015 Power Analyser Mains adapters for the HMC8015 Power Analyser Features Mains Adapter For HMC8015 Power Analyzer European socket (RS 144-8242 ) UK Type G socket (RS 144-8243 )
New items
P01120434B, Chauvin Arnoux

P01120434B, Chauvin Arnoux

CA8230 Power Quality Analyser Portable hand held single phase power quality analyzer ideal for maintenance, inspection and testing of electrical installations and electrical networks. It can be used for a snapshot of the main characteristics of a network and to track variations of the different parameters over time.,The multi-tasking measurement system simultaneously performs all functions required for the measurement of the various quantities, detection, continuous recording and display.,Comprehensive measurement capability enables a complete analysis of power and energy in single phase and balance three phase systems. Large colour VGA (320 X 240 pixels) graphical display Power measurement up to 250kW (dependant on clamp selection) 600V rms and up to 6,500A (with clamp) Harmonics (IEC 1000-4-7) display up to 50th order MIN, MAX, AVERAGE, PEAK and Crest Factor display W, VA, VAR power, DF, THD, Cos Short term voltage flicker calculation Recording, time stamping, and characterisation of disturbances including voltage overloads, brown- and blackouts, overshooting of powers and harmonic thresholds Calculation of the K factor for the current in transformer applications Personalised alarm settings enable up to 4096 events to be captured. Simultaneous recording of all parameters, alarms and motor start up currents. Rechargeable batteries RS232 direct output to PC CA8230: includes Dataviewer® software enabling screenshot capture; histogram or curve representations,; average value of numerous parameters according to time; management & log of measurement campaigns & report printing Select AC current probes separately :- Ampflex A193: 10 to 6500Aac (10Hz to 20kHz) 450mm long flexible probe MN93A: 0.2 to 120Aac (40Hz to 10kHz): Jaw size 20mm dia. Voltage range 6 VRMS to 600 VRMS AC+DC ±(0.5%+2pts) AC current range 5mA to 6500 A ±(0.5%+1pts) DC current range 1 A to 1700 A ±(1%+1pts) Fundamental frequency 40 Hz to 70 Hz Harmonics (IEC 1000-4-7) Up to 50th ...
FAQs
We offer free shipping for orders over £200 if delivery is in the UK. All other orders in the UK, shipping from £7.99 depending on the weight and measurement. Mainland Europe shipping charges start from £25. For all other countries shipping charges start from £50 for products like Power Quality Analyser Accessories and all others.
You can email us directly at sales@enrgtech.co.uk or via our website for any queries regarding Power Quality Analyser Accessories or any other product.
This depends on the Power Quality Analyser Accessories individual product and information that can be found on our website.
Yes, we offer special discounts on orders above £200 for Power Quality Analyser Accessories and all other products.
UK orders normally take between 2/3 working days. International orders normally take between 3/5 working days for all products including Power Quality Analyser Accessories.
Yes. We keep updating our stock frequently and if a product like Power Quality Analyser Accessories is not in stock then we will let you know.